ALM 48 PRODUCT OVERVIEW

 



Especially for those who require a economical transmitter with high accuracy we have developed the ALM series of transmitters. This series is limited to four different models, yet covering the entire range of MilliVolts, Pt100 and Thermocouples K, J and T. You will find the transmitters of the ALM-series easy to install and you will find an amazing accuracy on all models. Therefore, the ALM-series delivers you great value for money.



ALM48 features
• 2-wire railmount transmitter
• Analogue transmitter
• Available for Pt100 (RTD), thermocouple K,J or T or mV input
• Free scalable
• High accuracy (typical 0.2%)
• Optional zero shift
• Temperature linear output (Pt100 version)
• Voltage linear output (T/C version)
• 5 Year warranty


  SPECIFICATIONS
 


Power supply

14 – 40 VDC

Polarity protected

Yes

Power supply effect

0.002%/V

Output

4 – 20 mA

Load capability

(V[bat] – 14 V) / 20 mA

Sensor burn out

Upscale (max. 35 mA)

Zero drift

± 0.025%/°C

Span drift

± 0.010%/°C

Ambient Operating Temp.

-20...+80°C

Ingress Protection

IP30

Storage Temperature

-40...+100°C

Housing Material

Polyamide

Housing Dimension W x H x D

22.5 x 79 x 85.5 mm (0.89” x 3.11” x 3.37”)

Pt100

 

Range

-50 to +800°C

Zero adjustment Pt100

-50 to +50°C

Span adjustment Pt100

50 to 800°C

Optional zero shift Pt100

-50 to +350°C

Linearization

0.1%

Sensor lead effect

0.03°C/Ohm

Max. sensor line resistance

250 Ohm

Thermocouple

 

Range T/C K

0 to 1200°C

Range T/C J

0 to 900°C

Range T/C T

0 to 400°C

Zero adjustment T/C

-25 to +50°C

Span adjustment T/C

T/C K: 150 to 1200°C   T/C J: 150 to 600°C   T/C T: 150 to 400°C

Optional zero shift T/C

0 to +400°C

Cold junction drift

0.03°C/°C

Max. sensor line resistance

10,000 Ohm

mV

 

Range

0 to 160 mV

Minimum span

10 mV



Download a printable specifications sheet here.

  ORDER INFORMATION
 


To order specify model

ALM 48-R
Input Pt100

ALM 48-T-K
Input T/C K

ALM 48-T-J
Input T/C J

ALM 48-T-T
Input T/C T

ALM48-mV
Input mV


Please add -Z suffix to order with zero shift.