| Mounting on a standard DIN rail, the Mp 88800-R features include small minimum span; complete linearization; wide power supply capability; selectable upscale/downscale; ATEX and FM approved versions available, high loop-drive capability and 5 year warranty against failure. |
 |
Mp88800-R features
2-wire microprocessor based rail-mount transmitter Mp 88800-R
• Microprocessor-Based • Pt100 (RTD) Input only • Fully Linearized • ATEX and FM approved versions available • High Accuracy • 5-Year Warranty |
| |

Input RTD |
Pt100 |
Minimum Span |
25°C |
Output |
4..20 mA or 20..4 mA |
Linearization |
On / Off |
Supply |
10..40 VDC, Polarity Protected |
Supply Effect |
0.02%/V |
Max. Ripple |
10 V PP. Min Vbat=10 VDC |
Zero Drift |
± 0.02%/°C or ±0.02°C/°C |
Span Drift |
± 0.01%/°C or ±0.01°C/°C |
Long Term Drift |
± 0.1%/Year |
Excitation Current, RTD |
0.1 mA |
Sensor Lead Resistance, RTD |
500 Ohm max. |
Sensor Lead Resistance Effect |
0.01°C/Ohm |
Open Circuit Detection |
Upscale / Downscale |
Load Capability |
Vbat-10V / 20 mA |
Startup Time |
30 sec. |
Warmup Time |
5 Min. |
Ambient Operating Temp. |
-40...+ 85°C. |
Storage Temperature |
-40...+100°C. |
Housing Material |
Makrolon |
Housing Dimension W x H x D |
22.5 x 75 x 99 mm (0.89” x 2.92” x 3.9”) |
|
|
| |
Model
MP88800-R
-R = Pt100 input only (default)
Options
IF / CW / EX
Options Explained
-IF = Interface and Software
-EX = Intrinsically Safe Approval
ATEX Ex II 1 G EEx ia IIC T4..T6
|
|
| |
Serial interface software V3.5 August 2008 (4.5 MB) |
|
| |
This software program is suitable for all microprocessor based transmitters using S-Products' interface for connection to your computer's serial port.
SPRO_MpUser_V35.exe
Please read the readme.1st or install.html file included in zip file for installation instructions.
|
|
| |
USB interface software V3.5 August 2008 (4.8MB) |
|
| |
This software program is suitable for all microprocessor based transmitters using S-Products' interface for connection to your computer's USB port.
SPRO_MpUser_V35 (USB).exe